Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Info
Solution Diagnostics Setting permits you to determine the firmware and software program variations, examination status of “design particular” system parts and sensing units, as well as change state of elements where suitable (i.e.– compressor on/off, etc.).
Enabling Solution Mode: To enable Solution Mode, press and hold the “WARMER” switch while pressing the “COLDER” switch 4 times within five seconds.
After entering Service Setting, the very first number that you will see shows the software program design number for the particular device you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the initial number you will certainly see is 11. See chart below for equivalent design and software program reference.
The 2nd number you will see suggests the software program variation release. For instance, if you see 44 on the display panel it shows software version 4.4.
Diagnostics:
While in Service Setting, press the “SET” switch to tip with Tests 0-9. The very first figure of the display will show the examination number. The second number shows the current state of each component under test and also is shown as “1” getting on, CLOSED, or SHORTED and “0” being OFF or OPEN. Examinations 0 and also 1 expose an open or shorted condition detected at the sensing unit inputs. Tests 2 through 6 permit you to turn loads ON with the “WARMER” button and also OFF with the “COLDER” switch. Examinations 7 through 9 confirm state change of the door changes and/or magnetic reed sensing unit. The part tests offered are defined in Offered Element Tests chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Ice forms in inlet tube to ice maker | Water pressure is low | Water pressure is low between 35 – 100 pounds per square inch. A minimum pressure of 35 pounds per square inch is recommended for refrigerators with water filters. |
Freezer temperature is too high. | Adjust freezer controls. Freezer is recommended to be approximately 0oF (-18oC) |